Beauty Equipment - MK-3010E's Description:

Detailed Product Description
Face freckle, age-spot, hereditary black mole, and other pigmentation, red face, red capillary, distillers grain nose, thick pore, remove black acne, cure all kinds of folliculitis, acne, acne spot, eye cancer freckle, character freckle, improve panda eye, white the skin, remove extra hair, lift up the breast to prevent it distortion, and aging.
Chapter 1 System Overview

I.Equipment description
1.Curing system

A high-strength pulse photon curing to achieve delicate skin under the curing principles based on photons selective heat absorption effects; this system is composed of the three parts: main equipment cabinet, control panel, strong photon intelligent curing head.

2.Intelligent system
Microcomputer intelligent control system, intelligent identification system, intelligent chip integration

3.Detecting system
High-resolution, high-pixel, low-illumination photo transfer system; high-lucidity TFT LCD analysis syste

II.Curing scope

1.This equipment is designed to make skin delicate and remove hair with curing effects for:

A Blood vessel disease, including capillary vessel dilatation, skin reddening, and red nose tip caused by grog blossom;
B Pigment disease, including fleck, skin splash, skin color spot, skin sunburn and sunning aging;
C.Coarse pore, skin roughness, elasticity deficiency and acne;
D Removal of fine wrinkles and delay of skin ageing;
E Hair removes.

2.This equipment effectively cures the locations in face, neck, breast and limbs.

3.This equipment is capable to detect and diagnose troubled skins with high lucidity and resolution.


II.Complications

Potential complications may be encountered in aesthetic IPL procedures, in particular if inappropriate IPL settings are used. It is very important to advise the patient that during the treatment some complications may occur:

*Hypo or hyperpigmentation may occur if the client has had sun exposure within less than 4 weeks before and after treatment.

*Burn marks on the skin may occur if the client was not properly shaved before treatment, or operator applied too much energy on the treated area.

*Blisters and / or hypo or hyperpigmentation may occur when treating dark skin without precautions.

*Zebra stripes may occur if you are treating a client using too much gel and the light is flashing out from the sides of the applicator or when not being careful about overlapping when treating the client.
During the treatment, the patient should always report every sensation.

III.Technical parameter
Curing light: high-strength pulse photon
Transfer system: sapphire
Wavelength: 530-1100nm (SR), 610-1100nm (HR)
Energy density: 15-50J/cm2
Spot size: 8*40mm
Pulse sequence: 2-15 pulse
First pulse width: 1.0-20ms
First pulse intermission: 3.0-50.0ms
Second pulse width: 0.5-10ms
Second pulse intermission: 2.0-50.0ms
Cooling system: water-cooling + air-cooling + semiconductor refrigeration
Power supply: 220V , 110V
Weight: 48kg
Photo system: CCD768H*494(V) 410000 pixel
Display system: TFT LCD display system
Chapter 2 Safety Description

This equipment is one kind of safe and reliable beautifying equipment designed to make skins delicate and remove hair; previously-trained qualified beautification professionals and medical care personnel are able to use this equipment in a safe manner so that as it is properly operated and maintained.

I.Safety warning
A Except for the technical personnel authorized by our company, any other person is not allowed to examine or repair IPL, especially the interior of this equipment, including internal adjustment of power supply, cooling system, optical elements, and strong photon curing head, etc.
B.Please note that dangerous high voltage is present with this equipment.
C.This equipment cannot be repaired unless it is shut off and disconnected of power supply.
D The photon conductive crystal must be kept constantly clean, and any coupling glue is not allowed to contaminate the interior of photon head.
E.If photon curing head is found to be leaking water, this equipment must not be started; and if it has been started, then it must be immediately shut off.

II.Strong photon warning
A Strong photon may damage eyes, or cause burning or burn injury; all reliable preventative and protective measures must be taken during application.
B Over-heat damage to skin may be caused if excess quantity of photon is released onto the locations under curing, and hyperplasia or shrinkage or color spot sediment may be subsequently caused.
C When high strength pulse photon is being released, both patients and beauticians must wear preventative and protective

Beauty Equipment MK-3010E on sale